- 다공질 치과용 임플란트 설계를 위한 육각가공체의 역학 분석
- ㆍ 저자명
- 김남식,Kim. Nam-Sic
- ㆍ 간행물명
- 대한치과기공학회지
- ㆍ 권/호정보
- 2011년|33권 4호|pp.307-312 (6 pages)
- ㆍ 발행정보
- 대한치과기공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Purpose: The purpose of this study is a porous cube mechanical analysis for the dental implant. Methods: The porous cube with a side length of 10mm was designed for dental implant. To choose proper design, porous hexagon with a side 10mm which was drilled as a regular hexagon with diameter 0.8mm, 1.0mm, 1.2mm and a side 0.4mm, 0.5mm, 0.6mm each using Computer AUTO CAD(Autodesk, 2008). Each cube was carried out in the mechanical analysis. Results: The result of mechanical analysis was observed that the H0.8 was minimum stress 0.045068MPa, maximum stress 9.4565MPa and minimum strain $0.00389{ imes}10^{-4}Mpa$, maximum strain $0.816{ imes}10^{-4}Mpa$, the H1.0 minimum stress 0.001147MPa, maximum stress 9.099MPa and minimum strain $0.000099{ imes}10^{-4}Mpa$, the maximum strain $0.784{ imes}10^{-4}Mpa$, the H1.2 minimum stress 0.099393MPa, maximum stress 13.137MPa and minimum strain $0.0112{ imes}10^{-4}Mpa$, maximum strain $1.13{ imes}10^{-4}Mpa$. Conclusion: The mechanical analysis of porous hexahedron was that H1.0 is the best result. It will be applicable to the porous implants.