- 수평 사각 채널에서의 상 압력 강하
- ㆍ 저자명
- 임태우,유삼상,김환성,Lim. Tae-Woo,You. Sam-Sang,Kim. Hwan-Seong
- ㆍ 간행물명
- 水産海洋敎育硏究
- ㆍ 권/호정보
- 2013년|25권 3호|pp.625-631 (7 pages)
- ㆍ 발행정보
- 한국수산해양교육학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Two-phase pressure drop experiments were performed during flow boiling to deionized water in a microchannel having a hydraulic diameter of $500{mu}m$. Tests were made in the ranges of heat fluxes from 100 to $400kW/m^2$, vapor qualities from 0 to 0.2 and mass fluxes of 200, 400 and $600kg/m^2s$. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. From the experimental results, it is found that the two phase multiplier decreases with an increase in mass flux. Measured data of pressure drop are compared to a few available correlations proposed for macroscale and mini/microscale. Among the separated flow models, the correlation model suggested by Lee and Garimella predicted the frictional pressure drop within MAE of 47.2%, which is better than other correlations.