- 국내 이유자돈사 환기시설 실태 조사
- ㆍ 저자명
- 이준엽,전중환,송준익,Lee. Jun-Yeob,Jeon. Jung-Hwan,Song. Jun-Ik
- ㆍ 간행물명
- 축산시설환경학회지
- ㆍ 권/호정보
- 2014년|20권 1호|pp.9-14 (6 pages)
- ㆍ 발행정보
- 한국축산시설환경학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This survey was conducted to give the basic information for ventilation systems of weaned pig house to establish the acceptable ventilation system in Korea. A total of 11 farms were surveyed in this study and 1 more farm in each province was regionally selected. The general information, inlet and outlet ventilation system, alley in house, space allowance of weaned pigs and manure management were surveyed. Space allowance of weaned pig in 82% of surveyed farms met the legal standard. Side wall inlet and outlet ventilation system were 82% and 73% of surveyed farms, respectively. Moreover, 73% farms have alley in the pig house to control temperature of inlet air. In this survey, both planar slot and circular duct inlet system and side wall fan outlet system could be a favorable ventilation system in weaned pig house.