자료유형
발행기관
- 한국탄소학회(9)
- 인문사회과학기술융합학회(8)
- 대한생리학회-대한약리학회(5)
- 대한수의학회(5)
- 물리치료재활과학회(4)
- 대한신경계작업치료학회(2)
- 미디어스토리텔링학회(2)
- 한국기초간호학회(2)
- 한국정보과학회(2)
- 대한기계학회(1)
- 대한치과이식임플란트학회(1)
- 제어로봇시스템학회(1)
- 한국교원대학교 뇌기반교육연구소(1)
- 한국습지학회(1)
- 한국열환경공학회(1)
- 한국청각언어재활학회(1)
- 환태평양유아교육연구학회(1)
간행물
- CARBON LETTERS(9)
- 예술인문사회융합멀티미디어논문지(8)
- THE KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY(5)
- JOURNAL OF VETERINARY SCIENCE(4)
- PHYSICAL THERAPY REHABILITATION SCIENCE(4)
- JOURNAL OF KOREAN BIOLOGICAL NURSING SCIENCE(2)
- 미디어스토리텔링(2)
- 재활치료과학(2)
- 정보과학회논문지. JOURNAL OF KIISE. 시스템 및 이론(2)
- ASIA-PACIFIC JOURNAL OF RESEARCH IN EARLY CHILDHOOD EDUCATION(1)
- AUDIOLOGY AND SPEECH RESEARCH(1)
- BRAIN, DIGITAL, & LEARNING(1)
- JOURNAL OF DENTAL IMPLANT RESEARCH(1)
- KOREAN JOURNAL OF VETERINARY RESEARCH(구 대한수의학회지)(1)
- 대한기계학회논문집(1)
- 열환경공학(1)
- 제어-로봇-시스템학회 논문지(1)
- 한국습지학회지(1)
-
Detecting Collisions in Graph-Driven Motion Synthesis for Crowd Simulation
성만규, Sung. Man-Kyu 한국정보과학회 정보과학회논문지. Journal of KIISE. 시스템 및 이론 9 Pages
한국정보과학회 정보과학회논문지. Journal of KIISE. 시스템 및 이론 2008, Vol.35 No.1 44-52 (9 pages)
본 논문에서는 모션켑쳐데이타를 이용한 두 캐릭터간의 빠른 충돌감지에 대한 연구를 논의한다. 본 연구의 목적이 군중 시뮬레이션이기 때문에, 제안한 알고리즘은 캐릭터를 실린더 형태로 모델링 한 후에 Rough한 충돌감지를 목표로 한다. 이를 위해 계층적인 바운딩 박스 데이타 구조인 MOBB를 제안한다. MOBB는 모션클립에 대한 시공간 바운딩 박스이며, 제안된 알고리즘에 대한 테스트 결과 2배 이상의 속도 향상이 있음을 밝힌다. -
The Role of the Pattern Edge in Goldfish Visual Motion Detection
Sun-HeeKim, Chang-SubJung 대한생리학회-대한약리학회 The Korean Journal of Physiology & Pharmacology 5 Pages
대한생리학회-대한약리학회 The Korean Journal of Physiology & Pharmacology 2010, Vol.14 No.6 10 413-417 (5 pages)
To understand the function of edges in perception of moving objects, we defined four questions to answer. Is the focus point in visual motion detection of a moving object: (1) the body or the edge of the object, (2) the leading edge or trailing edge of the object, (3) different in scotopic, mesopic and photopic luminance levels, or (4) different for colored objects? We measured the Optomotor Response (OMR) and Edge Triggering Response (ETR) of goldfish. We used a square and sine wave patterns... -
Intraocular Injection of Muscimol Induces Illusory Motion Reversal in Goldfish
Sang-YoonLee, Chang-SubJung 대한생리학회-대한약리학회 The Korean Journal of Physiology & Pharmacology 5 Pages
대한생리학회-대한약리학회 The Korean Journal of Physiology & Pharmacology 2009, Vol.13 No.6 10 469-473 (5 pages)
Induced activation of the gamma-aminobutyric acidA (GABAA) receptor in the retina of goldfish caused the fish to rotate in the opposite direction to that of the spinning pattern during an optomotor response (OMR) measurement. Muscimol, a GABAA receptor agonist, modified OMR in a concentration- dependent manner. The GABAB receptor agonist baclofen and GABAC receptor agonist CACA did not affect OMR. The observed modifications in OMR included decreased anterograde rotation... -
Acute effect of self-myofascial release using a foam roller on the plantar fascia on hamstring and lumbar spine superficial back line flexibility
Kwang-sun Do, Jae-eun Kim, Jong-eun Yim 물리치료재활과학회 Physical Therapy Rehabilitation Science 6 Pages
물리치료재활과학회 Physical Therapy Rehabilitation Science 2018, 제 7권 제 1호 7 35-40 (6 pages)
Objective: The purpose of this study was to investigate the immediate effect of applying self-myofascial release (SMR) to the plantar fascia using a foam roller on hamstring and lumbar spine superficial back line (SBL). Design: Randomized controlled trial. Methods: Thirty-one healthy adults agreed to the method and purpose of the study. Selection and exclusion criteria were screened, and baseline measurements for the Toe Touch test and passive straight leg raise (PSLR) test were obtained. The... -
A comparison of vital capacity values and respiratory muscles activities on pelvic tilt position
Seo-Young Jang, Su-Young Lee 물리치료재활과학회 Physical Therapy Rehabilitation Science 7 Pages
물리치료재활과학회 Physical Therapy Rehabilitation Science 2015, 제 4권 제 2호 8 108-114 (7 pages)
Objective: The purpose of this study was to examine the effect on vital capacity (VC) and inspiratory muscle activation according to the anterior and posterior pelvic tilt positions. Design: One group pretest-posttest design. Methods: Twenty-six healthy adult men and women, age 19 to 27 years, volunteered to participate in this study. Forced vital capacity (FVC), and forced expiratory volume in 1 second (FEV1) were measured by desktop spirometer in the pelvic positions during respiration, and... -
The impact of head repositioning accuracy and proprioception on cervical stabilization exercise in healthy adults
Kyung Wook Kang, Dae Won Kang, Gu Ye Kwon, Han Byul Kim, Kyoung Min Noh, Gi Hyun Baek, Jin Kwan Cha, Hyun Hee Kim 물리치료재활과학회 Physical Therapy Rehabilitation Science 6 Pages
물리치료재활과학회 Physical Therapy Rehabilitation Science 2015, 제 4권 제 1호 9 49-54 (6 pages)
of the graph paper was measured three times with the averaged value used as the head repositioning accuracy. Neck proprioception was measured by a cervical range of motion device (CROM). Subjects wore the CROM tester and were to look straight ahead while bending his/her neck. Subjects were instructed to perform extension, lateral flexion and rotation, and the values were then measured and recorded. The measurements were performed pre-intervention, and after cervical stabilization exercise.... -
Non-invasive quantification of hepatic fat content in healthy dogs by using proton magnetic resonance spectroscopy and dual gradient echo magnetic resonance imaging
Francesca Del Chicca, Andrea Schwarz, Dieter Meier, Paula Grest, Annette Liesegang, Patrick R. Kircher 대한수의학회 Journal of Veterinary Science 7 Pages
대한수의학회 Journal of Veterinary Science 2018, 제 19권 제 4호 14 570-576 (7 pages)
The objective of the present study was to describe two non-invasive methods for fat quantification in normal canine liver by using magnetic resonance imaging (MRI) and spectroscopy. Eleven adult beagle dogs were anesthetized and underwent magnetic resonance examination of the cranial abdomen by performing morphologic, modified Dixon (mDixon) dual gradient echo sequence, and proton magnetic resonance spectroscopy (1H MRS) imaging. In addition, ultrasonographic liver examination was performed,... -
Biceps femoris muscle transposition for treatment of cranial cruciate ligament rupture in small breed dogs
Roberto Tamburro*, Stefania Pinna, Anna Maria Tribuiani, Alessandra Panacea, Fabio Carli, Antonio Venturini 대한수의학회 Journal of Veterinary Science 6 Pages
대한수의학회 Journal of Veterinary Science 2012, 제 13권 제 1호 13 93-98 (6 pages)
The purpose of this study was to evaluate a new extracapsular surgical technique for the treatment of cranial cruciate ligament rupture in small breed dogs. Nine small breed dogs (seven females and two males) weighing ≤ 15 kg were treated with biceps femoris muscle transposition (BFT). The duration of the BFT procedure was 20 min. Each patient underwent a standard clinical protocol and a questionnaire for the owners. Follow-up (at 1, 3, and 12 months postoperative) confirmed significant... -
Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs
Jinhwa Chang, Sujin Kim, Joohyun Jung, Heechun Lee, Hojung Choi, Dongwoo Chang, Youngwon Lee, Junghee Yoon, Mincheol Choi* 대한수의학회 Journal of Veterinary Science 7 Pages
대한수의학회 Journal of Veterinary Science 2011, 제 12권 제 4호 13 393-399 (7 pages)
The objective of our study was to determine individual and global glomerular filtration rates (GFRs) using dynamic renal computed tomography (CT) in Beagle dogs. Twenty-four healthy Beagle dogs were included in the experiment. Anesthesia was induced in all dogs by using propofol and isoflurane prior to CT examination. A single slice of the kidney was sequentially scanned after a bolus intravenous injection of contrast material (iohexol, 1 mL/kg, 300 mgI/mL). Time attenuation curves were created... -
Three-dimensional CT angiography of the canine hepatic vasculature
Yucheol Jeong, Changyun Lim, Sunkyoung Oh, Joohyun Jung, Jinhwa Chang, Junghee Yoon, Mincheol Choi* 대한수의학회 Journal of Veterinary Science 8 Pages
대한수의학회 Journal of Veterinary Science 2008, 제 9권 제 4호 11 407-414 (8 pages)
Eight Beagle dogs were anesthetized and were imaged using a single channel helical CT scanner. The contrast medium used in this study was iohexol (300 mg I/ml) and doses were 0.5 ml/kg for a cine scan, 3 ml/kg for an enhanced scan. The flow rate for contrast material administration was 2 ml/sec for all scans. This study was divided into three steps, with unenhanced, cine and enhanced scans. The enhanced scan was subdivided into the arterial phase and the venous phase. All of the enhanced scans...


전체 선택해제

총


