기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Erythropoietin 검사법(檢査法)에 관(關)한 연구(硏究)
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Erythropoietin 검사법(檢査法)에 관(關)한 연구(硏究)
  • Studies on Erythropoietin Bioassay Method
저자명
조경삼,노흥규,이문호,Cho. Kyoung-Sam,Ro. Heung-Kyu,Lee. Mun-Ho
간행물명
大韓核醫學會誌
권/호정보
1975년|9권 2호|pp.39-46 (8 pages)
발행정보
대한핵의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

It is the purpose of this paper to design the most preferable method of erythropoietin bioassay in Korea. Bioassay utilizing polycythemic mice are currently in general use for the indirect determination of erythropoietin. Assay animals are usually prepared either by transfusion or by exposure to reduced oxygen tension in specially constructed chamber. We prepared the polycythemic, mice by the specially constructed hypobaric chamber. We observed weights and hematocrits of the mice in the hypobaric chamber, then hematocrits and 72 hours $^{59}Fe$ red cell upatke ratio of the polycythemic mice induced by hypoxia after removal from the hypobaric chamber. We designed the method of erythropoietin bioassay according to the results obtained by above experiments. Then we measured the 72 hours $^{59}Fe$ red cell uptake ratio of the polycythemic mice with normal saline, normal plasma and anemic plasma according to the method we designed. The results are followed: 1. The hematocrits of the mice in hypobaric chamber increased to 74% in 14 days It is preferable to maintain the pressure of the chamber to 400mmHg for first 4 days then 300mmHg for last 10 days to reduce the death rate and time consuming in hypobaric chamber. 2. After removal from the hypobaric chamber, the 72 hours $^{59}Fe$ red cell uptake ratio decreased rapidly and maintained the lowest level from the fourth day to tenth day. 3. We design the method of erythropoietin bioassay according to the results of above experiment and to the half life of erythropoietin. 4. The Korean product S9Fe is mixture of $^{59}Fe;and;^{55}Fe$. And the $^{59}Fe$ red cell uptake ratio in normal mice was far less with Korean product $^{59}Fe$ than with pure $^{59}Fe$ of foreign product. So it is desirable to use pure $^{59}Fe$ in this method of erythropoietin bioassay. 5. Considering the cost, the technique, the time consuming and the sensitivity it is the most preferable method of erythropoietin bioassay in Korea using hypobaric chamber to induce the polycythemia.