- SCR 에 의한 직류회로차단기의 과부하차단특성개선
- ㆍ 저자명
- 박정후
- ㆍ 간행물명
- 한국어업기술학회지
- ㆍ 권/호정보
- 1978년|14권 2호|pp.89-95 (7 pages)
- ㆍ 발행정보
- 한국어업기술학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.