기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
일산화탄소중독(一酸化炭素中毒)의 약물치료효과에 관(關)한 실험적(實驗的) 연구(硏究) -과산화수소(過酸化水素) 관장법(灌腸法)을 중심(中心)으로-
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 일산화탄소중독(一酸化炭素中毒)의 약물치료효과에 관(關)한 실험적(實驗的) 연구(硏究) -과산화수소(過酸化水素) 관장법(灌腸法)을 중심(中心)으로-
저자명
최동욱,유근영,박항배,Choi. D.W.,Yoo. K.Y.,Park. H.B.
간행물명
예방의학회지
권/호정보
1980년|13권 1호|pp.13-18 (6 pages)
발행정보
대한예방의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The ultimate goal of treatment of carton monoxide poisoning is to promote dissociation of carboxyhemoglobin and to maintain arterial $PO_2$ above 50mmHg throughout the course of treatment to protect vital organs from damage caused by hypoxia. The hyperbaric chamber designed and manufactured for this purpose has obviousely made an enormous contribution and yet has several handicaps to be overcome by any means. These handicaps are: the financial impact to purchase the chamber (especially in a small, remote community), an extra manpower requirement to operate the device, limitation in the capacity of the chamber (one man type), and the possible hazard of oxygen intoxication and dysbarism. The primary objective of this study is to develope a new therapeutic measure as an alternative to the hyperbaric chamber when it is not available or contraindicated. The effect of intestinal perfusion with hydrogen peroxide has been studied by many investigators and was known to be an excellent way of extrapulmonary oxygen supply. the advantage of this method will include; 1) much more amount of oxygen is delivered to the tissue than one would expect from 100% saturation with oxygen at 1 ata, 2) the procedure is simple and most economical, 3) neither sophisticated equipment nor extra manpower is required. As a study preliminary to the clinical application, authors conducted a series of experiment to observe the effect of hydrogen peroxide enema on dissociation of carboxyhemoglobin in intoxicated rabbit blood. Using an animal gas chamber, 20 rabbits were exposed to CO gas of 6,000 ppm for 60 minutes. Ten rabbits of control group were given 10cc of warmed normal saline solution by reactal perfusion and for the other 10 of the experimental group, the same amount of 1% $H_{2}O_{2}$ solution was given by the same way. Two blood specimens were drawn from each rabbit: the first one immediately following the exposure and the second one after rectal perfusion, about 30 minutes after the first sampling. The result was as follows; 1) The decrease in carboxyhemoglobin concentration during the first 30 minutes in the control and experimental group were $18.18{pm}4.49%;and;23.03{pm}4.13%$ respectively shelving the significant difference (p<0.05) between the two groups. 2) Hemoglobin and hematocrit value showed no significant difference between two groups and not altered significantly by intestinal perfusion with $H_{2}O_{2}$.