기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
태양(太陽)에너지의 직접흡수식(直接吸收式) 수열판상(受熱板上)의 유체유동특성(流體流動特性)에 관(關)한 연구(硏究)
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 태양(太陽)에너지의 직접흡수식(直接吸收式) 수열판상(受熱板上)의 유체유동특성(流體流動特性)에 관(關)한 연구(硏究)
저자명
박이동,Pak. Ee-Tong
간행물명
태양에너지
권/호정보
1984년|4권 2호|pp.13-28 (16 pages)
발행정보
한국태양에너지학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Direct Absorption Receiver and Thermal Storage System is a complex problem. This paper describes only characteristic of fluid flow on the receiver. The fluid thicknesses of Molten Salts (Melting Point : $397^{circ}C$) flowing on the receiver of modified protopype ($10m{ imes}10m$) were calculated theorectically, changing the receiver slope from 60 degree to 85 degree (5 steps). The receiver temperatures were $430^{circ}C$ at the top part and $950^{circ}C$ at the low part. The flow thickness of the Molten Salts at the top part of the receiver are around 1.9mm in the case of maximum insolution ($50{ imes}10^6$juoule/sec; 58.898kg/sec of flow rate) and 2.0mm at the low part. In the case of 3/10 of maximum insolation (flow rate = 17.669kg/sec) the flow thickness at the top part are around 0.9mm and 0.4mm at the low part, and in the case of 1/10 of maximum insolation (flow rate = 5.889 kg/see) the flow thickness at the top part are around 0.6mm and 0.3mm at the low part. From experimental measurements of a normal fresh water thickness flowing on the model plate ($12.7cm{ imes}111.76cm$), around 0.8mm at the top part of the plate and around 0.7mm at the low part were obtained in the case of maximum insolation (flow rate = 0.12496 kg/see). In the case of 3/10 (flow rate = 0.03748 kg/see) and 1/10 (flow rate = 0.012496 kg/see) of maximum insolation, around 0.5mm and 0.4mm at the top part, and around 0.3mm and 0.2mm at the low part were obtained respectively. The reason why the thickness of the Molten Salts increase at the low part of the receiver only in case of maximum insolation is that decreasing rate of the viscosity of the Molten Salts is larger than decreasing rate of the density of the Molten Salts during temperature increase from the top to the low receiver plate and decrease of the fluid velocity in accordance with continuity principle. In all cases without the above maximum insolation, the thickness of the Molten Salts and the fresh water decreased at the low part of the plate because of gravity force effects rather than friction effects and of continuity principle. All simillar flow patterns were obtained through all cases of the insolation making an exception of only maximum insolation.