충전(充塡)된 아말감 제거시(除去時) 발생(發生)되는 수은증기량(水銀蒸氣量) 측정(測定)에 관(關)한 연구(硏究)
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 충전(充塡)된 아말감 제거시(除去時) 발생(發生)되는 수은증기량(水銀蒸氣量) 측정(測定)에 관(關)한 연구(硏究)
저자명
나긍균,민병순,최호영,박상진,Na. Keung-Kyun,Min. Byung-Soon,Choi. Ho-Young,Park. Sang-Jin
간행물명
大韓齒科保存學會誌
권/호정보
1984년|10권 1호|pp.85-92 (8 pages)
발행정보
대한치과보존학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The aim of this study was to examine the influence of the speed of grinding and coolants on mercury vaporization during amalgam removal. Forty amalgam filled stone dies were stored at $37^{circ}C$ and 100% relative humidity for 7 days prior to the beginning of the mercury vapor experiment and were divided into 4 different groups; In Group I; Used by high speed without coolant & evacuator during amalgam removal. In Group II; Used by high speed with coolant & evacuator during amalgam removal. In Group III; Used by low speed without coolant & evacuator during amalgam removal. In Group IV; Used by low speed with coolant & evacuator during amalgam removal. The amalgam specimens were removed in a 30-second time period and mercury vapor was collected with membrane filter at 27mm from the site of removal and 45 degree above there. Samples in Group II, IV were removed with coolant spray at a flow rate of 30 ml/min with high-velocity evacuator. Mercury vapor collected membrane filter was analysed by Atomic Absorption Spectrophotometer using cold vapor method. The results were as follows; 1. The mercury vapor levels were obtained all of the Groups. 2. The mercury vapor levels of the Group II, IV (with coolant & evacuator) were less than that of the Group I, III (without coolant & evacuator). 3. The highest mercury vapor level recorded during amalgam removal procedure was Group I (used by high speed without coolant & evacuator) and its record was $0.78{pm}0.09;mg/m^3$, which exceed the T.L.V. by 15 times. 4. The mercury vapor level of the Group IV (used by low speed with coolant & evacuator) was more than that of the Group II (used by high speed with coolant & evacuator), but its difference was not significant, statistically. (p > 0.05)