기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
병(病)-의원(醫院)의 X선촬영업무(線撮影業務)에 관한 실태조사(實態調査)
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 병(病)-의원(醫院)의 X선촬영업무(線撮影業務)에 관한 실태조사(實態調査)
  • Survey on Radiographic Works in Hospitals and Clinics
저자명
최종학,전만진,박성옥,임한영,김건중,허준,최종운,Choi. Song-Hak,Jeon. Man-Jin,Park. Sung-Ock,Lim. Han-Young,Kim. Keon-Chung,Huh. Joon,Choi. Jong-Woon
간행물명
대한방사선기술학회지
권/호정보
1984년|7권 1호|pp.3-11 (9 pages)
발행정보
대한방사선과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The major findings of this investigation on radiographic works in 125 medical institutions around Seoul and Kyung-Ki area, from March 1983 to February 1984, are summarized as follows. 1. The number of references provided on radiographic techniques were 3 to 5 in general hospitals (52.1%), in hospitals (58.5%), and clinics (44.5%), and only the 10.4% of general hospitals had 11 or more. 2. The relatively high percentages of 75.0% of general hospitals and 68.3% of hospitals have established the standardized radiographic methods for regions examined, but most clinics (61.1%) have not. 3. As a log system for the radiographic request, the method of "routine study, or all the x-ray examinations are marked as 0 on a printed form" was most commonly used by general hospitals (62.5%) and hospitals (51.2%), and "the doctors employ their own methods" in most clinics (44.6%). 4. In the 85.4% of general hospitals, the 68.3% of hospitals and the 38.9% of clinics, the data such as diagnosis, clinic history, purpose of x-ray examination were recorded on a radiographic request at all times, or at least in part. 5. On a scale of hardness and easiness of order of doctors, the greatest response was "fairly easy to understand", and the 37.5% of general hospitals responded as "sometimes hard". 6. In determining the standards for radiographic factors, the general hospitals (62.5%) and hospitals (65.9%) adapted mostly "a departmental check list", and the clinics (61.1%) used mainly "a personal decision". 7. In using the immobilizing devices, angligner, and radiographic accessories, the Percentages were high in general hospitals and hospitals on the one hand, and were low in clinics on the other. 8. A consideration with regard to the devices for an improvement of examination of the same patients was totally ignored by the 50.0% of clinics, the 26.8% of hospitals and the 20.8% of general hospitals. 9. The causes of re-examination were due largely to patients (33.6%), and followed proportionately by incorrect exposure (22.8%), errors in positioning (22.0%), film processing faults (9.2%), conditions of x-ray equipments (8.8%), and quality of x-ray films (3.6%). 10. The conference on radiography was conducted regularly or irregularly by the 87.5% of general hospitals, the 56.1% of hospitals, and the 27.7% of clinics, and the meeting was proceeded only by radiologic technologists.