기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
박동류 및 비박동류에 의한 체외순환의 비교
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 박동류 및 비박동류에 의한 체외순환의 비교
저자명
선경,백광제,김요한,임창영,김광택,김학제,김형묵,Seon. Gyeong,Baek. Gwang-Je,Kim. Yo-Han,Im. Chang-Yeong,Kim. Gwang-Taek,Kim. Hak-Je,Kim. Hyeong-Muk
간행물명
大韓胸部外科學會誌
권/호정보
1985년|18권 2호|pp.182-192 (11 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

[here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.