기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
배란유도주기에 따른 초음파검사와 기초체온표의 비교분석
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 배란유도주기에 따른 초음파검사와 기초체온표의 비교분석
  • A Comparative Analysis of Basal Body Temperature to Ultrasound, as a Method of Ovulation Detection in Induced Ovulatory Menstrual Cycles
저자명
최욱,서병희,이재현,Choi. W.,Suh. B.H.,Lee. J.H.
간행물명
大韓不妊學會雜誌
권/호정보
1985년|12권 2호|pp.25-37 (13 pages)
발행정보
대한생식의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Four points on the basal body temperature (B.B.T.) curve was correlated with the estimated time of ovulation, as determined by serial ultrasound in 50 induced menstrual cycles from 22 subjects. The time of ovulation was estimated by measuring the maximal diameter of follicles and observing the morphologic changes within the ovary from follicle to corpus luteum. The results were as following; 1. The diameter of the follicle measured at the day before disappearance was 21.1 mm on an average (S.D.: 2.14). The average follicular growth for 4 days before ovulation was measured at a rate of 2.8 mm/day, and rapid growth of follicle was observed 3.1 mm/day at the day before. 2. The changes associated with rupture of the follicles were the followings, in order of frequency; decrease in size(94%), disappearance of follicles(64%), fluid in the Cul-de-Sac(26%) and increased internal echoes(16%). 3. Only 20 of 50 cycles, exhibited a BBT dip and correlated with the estimated time of ovulation by ultrasound in 2 of which cases(10%). BBT nadir, 30 of 50 cycles, correlated in 5(16.7%). The first day of hyperthermic plateau(FDHP) and BBT coverline was exhibited in all cycles, correlated in 41(82%) and 35(70%) cases. 4. The relationship between the diameter of dominant dominant follicle, measured by ultrasound, and the basal body temperature curve were as following. During cycles in which dip was observed on the BBT curve, the follicular diameter were 10.5${pm}$2.12 mm on 4 days prior to the point (D-4), and 12.5${pm}$2.12 mm (D-3), 15.5${pm$2.12 mm (D-2), 17.0${pm}$1.41 mm (D-1) and 21.5${pm}$2.12 mm just prior to the dip (D-0). In the nadir; 9.6${pm}$1.67 mm (N-4), 12.8${pm}$1.79 mm (N-3), 16.2${pm}$1.92 mm (N-2), 18.2${pm}$2.17 mm (N-1) and 21.4${pm}$2.61 mm (N-0). In the First day of Hyperthemic Plateau (FDHP); 9.8${pm}$1.36 mm (F-4), 12.4${pm}$1.41 mm (F-3),15.1${pm}$1.57 mm (F-2), 18.1${pm}$1.67 mm (F-1) and 21.2${pm}$2.25 mm (F-0). In the BBT coverline endopint; 9.9${pm}$.39 mm (C-4), 12.5 ${pm}$1.44 mm (C-3), 15.2${pm}$1.64 mm (C-2), 18.0 ${pm}$1.69 mm (C-1), and 21.2${pm}$2.31 mm (C-0). 5. The relationship between the ultrasonographic signs of ovulation and the basal body temperature curve were as following. The BBT dip correlated with the ovulation in 2 cases, which revealed decrease in follicular diameter (100%), fluid pattem in the Cul-de-Sac (1 case, 50%) and complete disappearance of follicle (1 case, 50%). In the nadir (5 cases); the ultrasonographic signs of ovulation were decrease in follicular diameter (5 cases, 100%), fluid pattern in the Cul-de-Sac (1 case, 20%) and complete disappearance of follicle (3 cases, 60%). In the First day of Hyperthermic Plateau (41 cases); decrease in follicular diameter (40 cases, 97.6%), fluid pattern in the Cul-de-Sac (11 cases, 26.8%), appearance of internal echo and thickening of the wall (6 cases, 14.6%) and com plete disappearance of follicle (28 cases, 68.3%). In the BBT coverline endpoint (35 cases); decrease in follicular diameter (33 cases, 94.3%), fluid pattern in the Cul-de Sac (9 cases, 25.7%), appearance of internal echo and thickening of the wall (5 cases 14.3%) and complete disappearance of follicle (20 cases, 57.1%).