기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
이종조직판막의 장기임상성적
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 이종조직판막의 장기임상성적
저자명
김종환
간행물명
大韓胸部外科學會誌
권/호정보
1987년|20권 2호|pp.289-299 (11 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

A total of 1,239 patients had cardiac valve replacement using 1,514 substitute valves at Seoul National University Hospital from 1968 to 1986. Of the total substitute vales, 84.9% were the glutaraldehyde-treated xenograft valves. Six hundred ninety-four patients who had 820 bioprosthetic tissue valves were studied for their clinical characteristics. They were a total and consecutive cases to the end of the study. Four hundred sixty-four patients had the lonescu-Shiley pericardial valves: MVR 291, AVR 66 and MVR+AVR 107; 163 had the Hancock porcine valves; 46 had the Angell-Shiley porcine valves; and 21 had the Carpentier-Edwards porcine valves. Five hundred forty patients underwent single valve replacement: MVR 460, AVR 76 and TVR 4; 154 had multiple valve replacement: MVR+AVR 141, MVR+TVR 12 and one triple valve replacement. Additional surgery was necessary in 22.3% of the cases. Operative mortality rate within 30 days of surgery was 6.77% for the total patients: 5.2% and 4.2% with MVR, 13.6% and 12.5% with AVR, and 7.5% and 7.4% with MVR+AVR using the lonescu and the Hancock valves respectively. A linealized annual late mortality rate was 2.56%/patient-year. Six hundred forty-three operative survivors were followed up for a total of 1482.7 patient-years [a mean 27.7 months], and the follow-up rate was 67.7%. The Idealized complication rates were: 2.02% emboli/patient-year, 0.94% bleeding/patient-year, 1.21% endocarditis/patient-year, and 3.84% overall valve failure/patient-year. A linealized rate of primary tissue failure was 0.87%/patient-year. Actuarial survival rates including the operative mortality were: 87.8*2.6%, 82.3*4.9% and 82.2*4.7% with MVR, AVR and MVR+AVR using the lonescu valves at 4 years after surgery respectively; and they were 88.0*4.1% with MVR at 8 years, 82.3*4.9% with AVR at 4 years and 84.9*7.0% with MVR+AVR at 6 years after surgery using the Hancock valves respectively. Probabilities of freedom from thromboembolism were 89.8*6.3% with MVR using the lonescu valves at postoperative 5 years and 89.2*3.8% with MVR using the Hancock valves at postoperative 7 years, and 93.3*3.9% with AVR using the lonescu valves at postoperative 5 years. None had embolic complication after AVR using the Hancock valves. Probabilities of freedom from valve failure [according to the Stanford criteria] were 81.0*7.1% with MVR using the lonescu valves at postoperative 4 years and 57.4*12.5% with MVR using the Hancock valves at postoperative 9 years. These clinical results prove the excellent antithrombogenicity of the glutaraldehyde-treated xenograft substitute valves and confirm the previously speculated rate of tissue failure. At the present situation, it may be concluded that there is a room for the further development of more durable bioprosthetic valves.