기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
실험적 골파괴와 골형성에 대한 방사선학적 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 실험적 골파괴와 골형성에 대한 방사선학적 연구
  • RADIOLOGIC STUDY OF THE EXPERIMENTALLY PRODUCED BONE DESTRUCTION AND BONE FORMATION
저자명
최순철,안형규,Choi. Soon-Chul,Ahn. Hyung-Kyu
간행물명
齒科放射線
권/호정보
1988년|18권 1호|pp.13-25 (13 pages)
발행정보
대한구강악안면방사선학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Bone destruction was induced experimentally by the insertion of a bit of the arsenic compound into the pulp chambers of the right premolars and the artificial bone defects were produced in the periapical regions of the left premolars in 7 dogs. The serial standardized periapical radiographs using aluminum stepwedge attached to the XCP instruments, and resin bite blocks were taken following insertion of arsenic compound and at 2, 4, 7, 10, 14, 17, 21, 24 and 28 days in case of bone destruction and following bone injury and weekly thereafter for a total of 14 weeks in case of bone formation. The errors of the method were determined with error estimators described by the Duinkerke. All radiographs were evaluated by the visual examination after joint evaluation by three dental radiologists and analysed with densitometer. The following results were obtained; 1. Analysis of the bone destruction process 1) The error of the method in estimating two distances proved to be small (S.D. for the measuring error; 0.04㎜, S.D. for the over-all error; 0.06㎜, S.D. for the positioning error; 0.05㎜) 2) The radiographic changes were observed after 7 days in 6 cases, 4 days in 1 case and 10 days in 1 case by the visual examination. 3) Aluminum equivalent values were diminished after 2 days and the diminution of 0.58±0.19㎜ was demanded to be detected by the visual examination. 2. Analysis of the bone formation process 1) The error of the method in estimating two distances proved to be small (S.D. for the measuring error; 0.03㎜, S.D. for the over-all error; 0.04㎜ S.D. for the positioning error; 0.04㎜) 2) The radiographic changes were observed after 2 weeks in 5 cases and 3 weeks in 2 cases by the visual examination. 3) Aluminum equivalent values were increased after 1 week and the increase of 0.45±0.15㎜ was demanded to be detected by the visual examination. 4) Aluminum equivalent values were increased continuously for 7 or 9 weeks but there as only extremely small change after 10 weeks.