기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
활로씨 사징증 환자에서 Blalock-Taussig 단락술후 폐동맥의 발달에 관한 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 활로씨 사징증 환자에서 Blalock-Taussig 단락술후 폐동맥의 발달에 관한 연구
저자명
정경영
간행물명
大韓胸部外科學會誌
권/호정보
1989년|22권 4호|pp.594-600 (7 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Primary intracardiac repair of tetralogy of Fallot with low mortality and early good results, has been accomplished in recent years. But palliative procedures have been reserved for those hypoplastic pulmonary arteries, a hypoplastic left ventricle or anomalies of the coronary artery would make total correction difficult. And the Blalock-Taussig shunt operation is recognized as a standard and popular palliative procedure. I undertook a retrospective determination of the effect of the Blalock-Taussig shunt operation on the development of the main pulmonary artery and the right and left pulmonary arteries. Between January, 1980, and April, 1987, at the Severance Hospital, 16 patients were studied by cardiac catheterization and angiocardiography, before undergoing Blalock-Taussig shunting procedures for the palliation of severe symptoms of tetralogy of Fallot, and some time later, usually prior to a second procedure. The mean interval between catheterizations was 22.25 months. Patients with tetralogy of Fallot and pulmonary atresia or with an occluded shunt were not included. The primary and secondary angiograms of each patient were reviewed, and measurements of the diameter of the main pulmonary artery, the right and left pulmonary arteries, and the descending thoracic aorta were taken. The results are as follows; 1. The hematocrit decreased from 56.39% to 50.34%[p< 0.05], and the arterial oxygen saturation increased from 62.00 % to 81.31 %[p< 0.001] following shunt procedures 2. The ratio of the diameter of the right pulmonary artery plus the left pulmonary artery to the diameter of the descending thoracic aorta increased 1.30 k 0.28 times [p< 0.01]; but the ratio of the diameter of the main pulmonary artery to the diameter of the descending thoracic aorta increased 1.10 * 0.33 times, which was not. significant[p< 0.05]. 3. The interval between shunting and second catheterization was not related to the magnitude of change in the pulmonary arteries[r=0.141, p >0.05]. 4. The changes in the ratio of the diameter of the right pulmonary artery plus the diameter of the left pulmonary artery to the diameter of the descending thoracic aorta was inversely related to the initial ratio[r=0.757, p >0.001], but the change in the ratio of the diameter of the main pulmonary artery to the descending thoracic aorta was not related[r=0.059, p >0.05]. 5. There were no differences in enlargement of the pulmonary artery on the side of the shunt [ipsilateral] versus enlargement on the opposite side [p >0.05], nor according to the size of the shunt[p >0.05]. In conclusion, this study suggests that the Blalock-Taussig shunt is effective for the development of the right and left pulmonary arteries but not effective for the main pulmonary artery.