기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
우세우심실 또는 우단심실증에서의 변형 Fontan 수술
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 우세우심실 또는 우단심실증에서의 변형 Fontan 수술
저자명
백완기
간행물명
大韓胸部外科學會誌
권/호정보
1991년|24권 3호|pp.310-321 (12 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Between April 1986 and September 1990, 34 patients with a single or dominant right ventricle underwent modified Fontan procedure for definite palliation in Seoul National University Children`s Hospital. Their age at operation ranged from 8 months to 14 years [Mean 5.5 years]. The ventricular chamber was solitary and of indeterminate trabecular pattern in 6 patients. 28 patients had posteriorly located rudimentary chamber, all of which were trabecular pouches having no communication with outlet septum. The patterns of atrioventricular connection were common inlet[9], double inlet [11], left atrioventricular valve atresia [12] and right atrioventricular valve atresia with L-loop [2]. Pulmonary outflow tracts were atretic in 7 patients and stenotic in 26 patients. Major associated anomalies included anomalous systemic venous drainage [15], dextrocardia [12] and total anomalous pulmonary venous connection[3]. Shunt operations were previously performed in 13 patients and pulmonary artery banding and atrial septectomy in 1 patients. Surgery included intraatrial baffling in 26 patients, bidirectional cavopulmonary shunt in 13 patients, atrioventricular valve obliteration in 3 patients and atrioventricular valve replacement in 3 patients. Central venous pressure measured postoperatively at intensive care unit ranged from 18cm H2O to 28cm H2O [mean 23.2cm H2O]. Hospital mortality was 35.3% [12/34], all died out of low output syndrome. Suspected causes of low output syndrome include ventricular dysfunction [8], hypoplastic or tortuous pulmonary artery [2] and elevated pulmonary vascular resistance [2]. 19 patients had 31 major complications including low output syndrome [18], arrhythmia [4], acute renal failure [3] and respiratory failure [3]. Mortality rate was significantly higher in the groups receiving intraatrial baffling and AV valve replacement respectively [p<0.05]. 20 patients were followed up postoperatively with the mean follow-up period 15.0$pm$11.6 months. There were no late death and follow-up catheterization was performed in 10 patients. Mean right atrial pressure was 15.4$pm$6.8mmHg and ventricular contraction was reasonable in all but one case. Thus, Fontan principle can be applied successfully to all the patients with complex cardiac anomaly of single ventricle variety and better results can be anticipated with judicious selection of patient and improvement of postoperative care.