기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
이오네스큐 단고형 승모판의 내구성
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 이오네스큐 단고형 승모판의 내구성
저자명
김종환
간행물명
大韓胸部外科學會誌
권/호정보
1992년|25권 8호|pp.863-870 (8 pages)
발행정보
대한흉부외과학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The low profile Ionescu-Shiley pericardial xenograft valve had been initially introduced to have improved hemodynamic performance and expected superior durability, However, subsequent clinical reports and laboratory studies have repeatedly indicated early failure of the valve from mechanical reasons in valve design, A total and consecutive 169 patients underwent isolated MVR with the low profile Ionescu-Shiley valve at Seoul National University Hospital from November 1984 to October 1989 [Group ISLM]. Five patients [3.0%] died within 30 days of surgery, and early survivors were followed up for 734.9 patient-years [Mean$pm$SD, 4.9$pm$2.0 years], Late mortality rate was 0.136% /patient-year [pt-yr], Linearized incidences of major complications were: 0.953% embolism /pt-yr; 0.680% bleeding /pt-yr; 0.272% endocarditis /pt-yr; and 0, 408% primary tissue failure [PTF] /pt-yr, The actuarial survival was 99.4$pm$0.6%, and probabilities of from thromboembolism and from PTF were 90.7$pm$4.6% and 95.9$pm$2.6% at 8 years, respectively These results were compared with the clinical data from the 291 patients of isolated MVR with the standard Ionescu-Shiley valve at the same hospital during the period between October 1978 and June 1983 [Group ISUM], Group ISUM included 11% of patients younger than 15 years of age, whereas Group ISLM did no patient of this age. The mean age at the time of surgery was significantly younger in Group ISUM than one in Group ISLM [P<0.001]. Differences were not statistically significant in operative mortality, mean follow-up period and linearized incidences of thromboembolism, bleeding and endocarditis, between two groups, However, the linearized rate of PTF was lower [P<0.001] and probabilities of freedom fro PTF higher [P<0.001] in Group ISLM at least up to postoperative 8 years. While the features of PTF of the standard valve was predominantly degeneration with calcification and stenosis, the ones of the low profile valve was cusp tear and incompetence. It remains, however, to be seen whether the low profile valve fails mostly from mechanical reason, and further follow-up will still be necessary to determine the differences in mode of PTF of two valves.