- 접착성 레진 시멘트를 이용한 주조관의 피막후경과 유지력에 관한 연구
- ㆍ 저자명
- 정영완,조혜원,진태호,Jung. Young-Wan,Cho. Hye-Won,Jin. Tai-Ho
- ㆍ 간행물명
- 대한치과보철학회지
- ㆍ 권/호정보
- 1992년|30권 3호|pp.437-443 (7 pages)
- ㆍ 발행정보
- 대한치과보철학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study was performed to investigate the availability of adhesive resin cement for luting agent of cast crown. The resin cements used in this study were Panavia-Ex(Kuraray Co., Japan) and C & B-Metabond (Parkell Bio-Materials U.S.A.). Zinc phosphate cement was Flecks zinc cement(Mizzy Inc., U.S.A.) The film thickness of cast crown at gingival margin, lateral wall and occlusal surface was observed with measuring microscope(Modek MXT 70 Matsuzawa Seiki Co., Japan) and the retention of cast crown was measured with Instron Universal Test Machine (Instron Engineering Co., U.S.A.) The results were as follows : 1. The value of retention of cast crown was the highest in the use of Panavia-EX, followed by C & B-Metabond and 2inc phosphate cement, respectively. 2. There was no difference in film thickness among the three cements, but the film thickness in all cements was highest at occlusal surface.