- Foley 도관을 이용한 식도 이물 제거방법에 대한 새로운 고찰
- ㆍ 저자명
- 김경인
- ㆍ 간행물명
- 대한방사선의학회지
- ㆍ 권/호정보
- 1993년|29권 4호|pp.844-848 (5 pages)
- ㆍ 발행정보
- 대한영상의학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Removal of blunt esophageal foreign bodies using Foley catheter under a fluoroscopic guidance is a well recognized procedure. However, since this procedure is rather cumbersome and uncomfortable to the patient, the authors tried to find an easier and more convenient modified technique. For 10 patients with esophageal foreign body, we tried the method to the patient who is lying in the right lateral decubitus position and 3 assistants hold head. arms, trunk and legs of the patient without tilting the table and without using immobilizer. Foley catheter is inserted through nostril, nasal cavity and pharynx to esophagus. In order to identify the Foley catheter in esophagus, 0.025 inch short wire was inserted in the Foley catheter. The balloon of a Foley catheter was inflated by 10cc of air, and the syringe was kept attached to the Foley catheter during the procedure. After passage of the foreign body through the upper esophageal sphincter, the balloon was deflated immediately and the foreign body was removed through the mouth. We successfully removed in removing all the blunt esophageal foreign body with ease. This modified method is also fast, safe and efficient.