- 지하수를 이용한 양액냉각시스템 개발에 관한 기초연구
- ㆍ 저자명
- 남상운,손정익,김문기
- ㆍ 간행물명
- 生物生産시설환경
- ㆍ 권/호정보
- 1993년|2권 1호|pp.1-8 (8 pages)
- ㆍ 발행정보
- 한국생물환경조절학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Experimental and theoretical analyses were carried out to investigate the heat exchange characteristics of the nutrient solution cooling system utilizing ground water. The material of heat exchanger used in the experiment was polyethylene and the cross-flow type was adapted in which nutrient solution was mixed and ground water unmixed. For the exchanger surface area of 0.33$m^2$ and flow rates of ground water of 1-6$ell$/min, NTU(number of transfer units) and effectiveness of experimental heat exchanger were 0.1-0.45 and 10-35%, respectively. Therefore these results showed that the hydroponic greenhouse of 1,000$m^2$(300 pyong) with the ground water of 10$m^2$/day could cover about 55-70% of maximum cooling load in summer.