- 자기 공명 영상장치를 이용한 악관절 기능 장애에 관한 연구
- ㆍ 저자명
- 김재덕,Kim. Jae-Duk
- ㆍ 간행물명
- 齒科放射線
- ㆍ 권/호정보
- 1993년|23권 1호|pp.7-14 (8 pages)
- ㆍ 발행정보
- 대한구강악안면방사선학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The Internal derangement of temporomandibular joint disc was evaluated by using magnetic resonance imaging and arthrogram in 5 patients having reciprocal clicking or locking and in 5 normal subjects. Parasagittal multisections on both closed and open mouth were serially obtained by using a 1.5 Tesla MR system and surface coil with CSMEMP, MPGR. MR images obtained were analized by correlating with images of arthrograms. The obtained results were as follows: 1. Displaced meniscus was clearly delineated as dark structure on MR images other than on arthrograms of closed mouth view of patient having clicking or locking. 2. The deltoid white images of synovial fluid were identified in the glenoid fossa and on the posterior surface of condyle on open mouth view and partly depicted on closed mouth view, of parasagittal sections by MPGR. 3. The greyish image of joint fluid was identified on the posterior surface of condyle on the open mouth view of parasagittal sections by CSMEMP. 4. The structural relationship among condyle, meniscus, and fluid showed the variety of images on each parasagitta1 view.