Authors investigated the size distribution and mass fraction of dusts in work environment of Changwon industrial complex. Size distribution of suspended dusts in welding and grinding processes were evaluated using ambient cascade impactors. The mass median diameters of dusts were 0.25 to $0.60 mu m$ at welding sites and 1.20 to $1.92 mu m$ at grinding sites. Respirable mass fractions were 63.68 to 73.50% at welding sites and 43.24 to 51.47% at grinding sites. Respirable fractions were calculated from the size distribution data for the ACGIH criteria by the respirable particle mass. In case of dust removal system, electrostatic precipitator and bag filter were appropriate for welding process and grinding process, respectively.