- 장기 노출 $NO_2$ 간이 샘플러 개발에 관한 연구
- A Study on the Development of Long Term Exposure $NO_2$ Sampler
- ㆍ 저자명
- 이동인,김윤선
- ㆍ 간행물명
- 한국산업안전학회지
- ㆍ 권/호정보
- 1995년|10권 2호|pp.105-112 (8 pages)
- ㆍ 발행정보
- 한국안전학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The concentrations of $NO_2$ were measured to estimate a new developed long term exposure $NO_2$ sampler at Pusan City considering the meteorological factors from May to July, in 1994. The monthly mean concentration of $NO_2$ was 15.9 PPb and 36.2 ${mu}ell$/day $NO_2$ and their high values were shown in the downtown of Pusan City which show potential pollution due to the increase of traffic activities and micrometeorological factors In and around the City. As a result of statistical correlation between $NO_2$ concentration by new sampling method and $NO_2$ concentration by the handy air sampler and chemiluminescent nitrogen oxides analyzer, 1994, correlation coefficients were high(r=0.93) and showed more than 0.88 value in the high concentration data set, which was arbitrarily divided into 30${mu}ell$ $NO_2$ concentration in an attempt to further investigate these relationships. Therefore, use of new developed long term exposure $NO_2$ sampler is good for $NO_2$ measurement and valuable for estimation of air quality in the urban and Industrial area.