  • 생체내 혈중 납 표준물질의 제조
저자명
정규철,최호춘,Chung. Kyou-Chull,Choi. Ho-Chun
간행물명
예방의학회지
권/호정보
1995년|28권 4호|pp.863-873 (11 pages)
발행정보
대한예방의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{mu}g/L,;0.34{mu}g/L,;and;0.56{mu}g/L,;0.14{mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{pm}1.36{mu}g/100ml$ by Varian 30A, and $33.08{pm}0.82{mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{pm}1.98{mu}g/100ml(A),;40.89{pm}0.80{mu}g/100ml(B),;59.01{pm}1.38{mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6sim100.4%,;91.6sim101.9%,;90.3sim100.0%$ for A, B, and C SRMs, means were $56.46{pm}2.69{mu}g/100ml,;39.35{pm}1.89{mu}g/100ml,;57.40{pm}2.31{mu}g/100ml$, and measurement ranges were$52.88{pm}59.26{mu}g/100ml,;37.47{pm}41.68{mu}g/100ml,;54.80{pm}60.69{mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{mu}g/100ml;to;33.54{mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{pm}0.24{mu}g/100ml$, acceptable range by $CDC;25.18sim37.18{mu}g/100ml$), showing the concentrations of $25.91{pm}1.19{mu}g/100ml(L1),;34.16{pm}0.22{mu}g/100ml(L2),;35.68{pm}0.85{mu}g/100ml(L3),;30.95{pm}0.46{mu}g/100ml(L4)$ in a each samples.