기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
만곡 근관에서 엔진 구동용 Ni-Ti File과 초음파 기구에 의한 근관성형 능력의 비교
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 만곡 근관에서 엔진 구동용 Ni-Ti File과 초음파 기구에 의한 근관성형 능력의 비교
저자명
김현주,오원만,양규호,Kim. Hyun-Ju,Oh. Won-Mann,Yang. Kyuo-Ho
간행물명
大韓齒科保存學會誌
권/호정보
1995년|20권 2호|pp.758-767 (10 pages)
발행정보
대한치과보존학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The purpose of this study was to evaluate canal shaping ability after canal preparation by using engine-driven nickel-titanium file and endosonic file in curved canals. 30 mesiobuccal canals of molars extracted within recent 3 months were divided into 3 groups. Group I and group II were prepared by using engine-driven nickel-titanium Gates-Glidden drill type and the engine-driven nickel-titanium file type. Group III prepared by using en do sonic file. The image of preinstrumented canals was taken by X-ray. The image of postinstrumented canal was taken by X-ray in the same condition of preinstrumentation. A magnified X-ray image on magnifier screen was traced and then compared the preinstrumentated canal image with the postinstrumentated canal image by superimposing method. The following results were obtained : 1. In the change of canal curvature, the engine-driven nickel-titanium Gates-Glidden drill type showed the least change and the ultrasonically filing showed the greatest change. 2. In the percentage of canal enlargement, the engine-driven nickel-titanium file type was greatest at all level(p<0.05), the apex of all group was the greatest, the difference of ultrasonically filing group showed greater between apex and cervix. 3. The percentage of canal enlargement on convex side was greater than that of on concave side in apex of each group(p<0.05). In the ultrasonically filing group, both sides of canal enlargement showed sharply difference(p<0.01). 4. The percentage of canal enlargement on convex side was greater than that of on concave side in the third of cervix of the engine-driven nickel-titanium file type and the ultrasonically filling. The percentage of canal enlargement of convex and concave side in the third of middle of the engine-driven nickel-titanium Gates-Glidden drill type show a similar canal enlargement between convex side and concave side. As above result, the engine-driven nickel-titanium file type was greater in canal enlargement than the other instruments. The engine-driven nickel-titanium Gates-Glidden dirll type was efficient endodontic instrument for curved canal preparation because it was least change in canal curvature.