- 부가중합형 Silicone putty 인상재를 이용한 인상채득 방법의 정확성에 관한 연구
- ㆍ 저자명
- 제홍지,정창모,전영찬,황희성,Je. Hong-Ji,Jeong. Chang-Mo,Jeon. Young-Chan,Hwang. Hie-Seong
- ㆍ 간행물명
- 대한치과보철학회지
- ㆍ 권/호정보
- 1996년|34권 2호|pp.373-383 (11 pages)
- ㆍ 발행정보
- 대한치과보철학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
In order to compare the accuracy of impression method using addition silicone putty impression material, metal master die was fabricated with 4 cylindrical abutments that were similar in shape to mandibular arch. Among the 4 abutments, two(A, D) with 8mm width and 7mm height were formed in the 2nd molar regions and the other two(B, C) with 6mm width and 7mm height were on the canine regions. Impressions were taken using one-step putty wash impression technique and two-step putty wash impression technique by three different types of impression materials(Perfect, Express, Exaflex). Upon measuring the distance between the abutments on the model by three dimensional measuring machine, the percent of devitaion of the materials were obtained, rendering the following results. The results obtained are as follows : 1. There was no significant difference in accuracy in regard with the impression method between one-step putty wash impression technique and two-step putty wash impression technique using addition silicone putty impression material. 2. There were no difference in accuracy among with three different addition silicone putty impression materials. 3. All the distances between abutments on improved stone models increased in comparison with those on the metal master model.