기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
경피적 폐 세침흡인생검의 기흉 위험 요인
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 경피적 폐 세침흡인생검의 기흉 위험 요인
저자명
김상진
간행물명
대한방사선의학회지
권/호정보
1997년|37권 3호|pp.453-457 (5 pages)
발행정보
대한영상의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Purpose:Percutaneous fine needle aspiration biopsy is known to be a useful diagnostic method for the diagnosis of various pulmonary diseases. Its diagnostic yield is high, and it is safe, but complications such as pneumothorax can occasionally occur. We reviewed the complications arising after needle aspiration biopsy and analyzed the risk factors of pneumothorax. Materials and Methods:The medical records anf radiographic studies of 157 patients with various pulmonary diseases who underwent needle aspiration biopsy of the lung between 1990 and 1996 were retrospectively reviewed. The clinical features, treatment, and courses of complications were reviewed, and risk factors of pneumothorax such as depth and siza of lesion, diameter of needle, number of punctures, and obstructive pulmonary abnormalities were analyzed. Results:Complications occurred in 40 of 157 cases(25.5%), namely pneumothorax in 26(16.6%), hemoptysis in 11(7%), hemothorax in two(1.3%), and recurrence of malignancy at the site of aspiration in one(0.6%). When the patients were divided into three groups according to depth of lesion, there were significant difference in the incidence of pneumothorax;the results were as follows:less than 2cm, 12.0%;between 2 and 4cm, 24.1%;and larger than 4cm, 57.1%(p<0.05). In pulmonary function testing, FVC(forced vital capacity) of patients with pneumothorax was less than that of patients without(2.6$pm$0.9L vs 3.1$pm$0.8L, p<0.05), but FEV1(forced expiratory volume in 1 second), FEV1%(percentage of predicted FEV1), FEV1/FVC, and FVC% (percentage of predicted FVC) were not different between the two groups. The incidence of pneumothorax in patients with pleura-attached lesion(9%) was lower than that of those with non-attached lesion(26%, p=0.01). The age of patients, size of lesionm diameter of the needle, guidance methods and number of aspirations showed no signigicant relationship with pneumothorax. Conclusion:In needle aspiration biopsy of the lung, depth of lesion and passage of a needle through aerated lung are significant risk factors of pneumothorax.