기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
동주화학요법을 위한 동맥내 포트설치술
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 동주화학요법을 위한 동맥내 포트설치술
저자명
김현주,심형진,정헌영,사은진,박효진,송인섭,김양수,최영희,곽병국
간행물명
대한방사선의학회지
권/호정보
1998년|38권 5호|pp.801-806 (6 pages)
발행정보
대한영상의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Purpose : To evaluate, using various port systems, the technique and complications of intra-arterial portimplantation in visceral (mainly hepatic) arteries for intra-arterial chemoinfusion. Materials and Methods : Weretrospectively evaluated 30 cases of intra-arterial port implantation in 29 patients. Angiography was performedin all cases, and insertion of an implantable polyurethane port catheter was followed by angiographic exchangewhich, utilizing a .035" hydrophilic guide wire, targeted the artery. If a change in the direction of flow wasrequired, arterial flow control was performed, using an enbolie coil. In order to insert the subcutaneous portchamber, an incision approximately 4cm long was made at the puncture site and subcutaneous tissue was dissected.The port chamber was inserted into the subcutaneous pocket and fixed with a black-silk tagging suture. When thefemoral artery was punctured, the port chamber was inserted into the supra-or infrainguinal area; when the leftsubclavian artery was used, the port chamber was inserted into the lateral one third of the left clavicle. Theport systems used in the procedure were as follows : 5.8F Port-A-Cath (SIMS, Deltec, U.S.A.)(n=20) ; 5.2F A-Port(Therex, U.S.A.)(N=5); 5F PU-Anthron(Deny, Japan)(n=4) ; 5.2F R-Port(Therex, U.S.A.)(n=1). The subcutaneouschambers were inserted into the infrainguinal (n=22), suprainguinal (n=6) or subclavian area(n=2). Results : Theprocedure was technically successful in all 30 cases. Port catheter tips were located in the hepatic arteryproper(n=11), the right hepatic(n=9), gastroduodenal (n=6), common hepatic (n=2), inferior mesenteric (n=1) andinternal iliac artery(n=1). In 12 cases, flow was controlled using embolic coils. Follow-up study was performed in23 cases, with a mean follow up period of 55.8 (11-161) days. Complications were noted in four cases ; two wereprocedure related and two were catheter related. Conclusion : Intra-arterial port implantation is a safe procedureand can be performed easily by skilled radiologists; long-term observation is, however, still needed.eded.