- 경동맥의 초고속 조영증강 자기공명혈관조영술 : 경동맥과 경정맥의 식판별에 대한 시간 조정변수의 최적화
- ㆍ 저자명
- 권우철
- ㆍ 간행물명
- 대한방사선의학회지
- ㆍ 권/호정보
- 1998년|39권 5호|pp.825-830 (6 pages)
- ㆍ 발행정보
- 대한영상의학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Purpose : To investigate the optimal delay and acquisition time for discrimination of the arterial from the venous phase in ultrafast 3D contrast-enhanced MR angiography of the carotid artery. Materials and Methods : We reviewed the MR angiographic findings of 233 patients in whom carotid stenosis and cerebrovascular disease were suspected. On the basis of delay and acquisition time they were divided into four groups. In the first three, contrast material was injected manually, and after the optimal time, mechanical injection was used for the last group. On the basis of signal intensity of the carotid artery, image quality was graded in four steps. Discrimination of the arterial from the venous phase was graded in three steps, based on the degree of venous enhancement. Results : The best grade of image quality was 70% in the first group, 85% in the second, and 95% in the third. In discrimination of the arterial-venous phase, the most definite grade was 50% in the first group, 62%in the second, and 75% in the third. Between manual and mechanical injection groups, there was no significant difference in image quality and discrimination of the arterial-venous phase.Conclusion : These results suggest that for ultrafast 3D contrast-enhanced MR angiography of the carotid artery, with manual injection of contrast material, 8-second delay time and 7-second acqusistion time are optimal..