기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE
  • MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE
저자명
Jeon. Young-Chan
간행물명
대한치과보철학회지
권/호정보
1998년|36권 1호|pp.120-132 (13 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

This stusy was to investigate the marginal fitness of porcelain-fused-to- metal crown after succesive firing cycle. Main variables were the degree of marginal curvature of labiocervical margin and the type of alloy. The exaggerated marginal curvature(EMC) was created by additional reduction at the faciocervical wall of the normallized marginal curvature (NMC)-typed ivorine tooth by using milling machine. The difference in the shape was the mid facial margin was placed 2mm apical to cemento- enamel junction in labial surface. Three types of alloy were high noble, noble, and base metal alloy. Test specimens were divided into 8 groups and each group had 8 specimens. Sixty four ceramometal crowns were made totally. Measurement stages were following degassing, opaquing. body porcelain firing, and glazing, and measuring sites were 4. (midmesial, midfacial, middistal, and midlingual). Digital, travelling measuring microscope (0.5 um precision, Olympus. Japan) was used under ${ imes}250$ magnification. Within the limitation of this investigation, it was concluded as belows: 1. The pattern of marginal distortion was varied. Degassing stage was not a specific, causative stage that induce most of total marginal distortion during whole procedure fabricating a ceramometal crown. Body firing stage induced discrepancy relatively more than other firing stages. 2. The specimens that were Ni-based alloy and had EMC were distorted persistently following successive fabricating procedures. But marginal openings were decreased after glazing. 3. The release of metal grinding-induced stress was presumed as a cause that induce marginal distortion. 4. The amount of discrepancies of the labial and lingual margins were greater than that of the mesial and distal margin in the specimen that had EMC. 5. Silver-plated die was not enough to resist abrasion during repeated seating of metal copings on the die-holding device.