  • 정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구
  • Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery
저자명
김상환,류지옥,김백규,김영호,Kim. Sang Hwan,Ryu. Ji Ok,Kim. Baek Kyu,Kim. Yong ho
간행물명
大韓放射線治療技術學會誌
권/호정보
1999년|11권 1호|pp.43-48 (6 pages)
발행정보
대한방사선치료학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

Purpose : For practical application of the MR image for stereotactic radiosurgery, the target point achieved by acquisition of MR image in a relatively homogeneous phantom has to agree with the actual isocenter of irradiation in real radiosurgery and the amount of distortion of the MR image should be known. Materials and Methods : A dosimetric film with a random target point was inserted into a radish vertically and horizontally on axis Z and they were fixed with a headring. After image acquisition by stereotactic radiosurgery planning system, we achieved stereotactic coordinate of the target point and examined irradiation using the coordinate acquired as isocenter. After the irradiation, the film in the radish was developed and processed and the degree of coincidence between the target point marked on the film and the center of the radiation distribution. In order to measure the degree of distortion of the MR image in a different way, an acryl phantom was made and punctures were made at intervals of 1 cm and a drop of oil was dropped into it. Then, it was inserted into the radish vertically and horizontally on axis Z to acquire the MR image. Each coordinate was achieved and the estimation of distortion of MR image was made both in vertical and horizontal directions Results : The film from the radio was developed and for the one inserted vertically on axis Z, there was a good coincidence in the discrepancy between the target point marked on the film and the center of the radiation distribution. For the one inserted horizontally, the discrepancy between them was under 0.5 mm. As a result of estimating distortion of MR image using acryl, the discrepancy was under 0.45 mm in the case of the phantom inserted vertically on axis Z, and that of the one inserted horizontally was 1.4 mm. Conclusion : We were able to confirm good coincidence in homogeneous phantom in actual treatment position of radiosurgery using the MR image and the discrepancy measured in the analysis of distortion of the MR image did not exceed the permissible level. Therefore, it was evident the system of the hospital is suitable for radiosurgery using MR image.