- 저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향
- ㆍ 저자명
- 이건중,송현갑
- ㆍ 간행물명
- 한국농업기계학회지
- ㆍ 권/호정보
- 1999년|24권 4호|pp.343-350 (8 pages)
- ㆍ 발행정보
- 한국농업기계학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The ambient air is commonly used as low-temperature heat source for heat pump operation. However, the coefficient of performance(COP) of the air to water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem, the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1,495.4, 1,794.5$ extrm{cm}^2$)was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The COP improvement of the heat pump could be achieved by the AVACTHE installation when below -5$^{circ}C$ of the ambient air temperature.