- 거대 점 오염원의 플룸에 의한 시정 장애 효과 연구
- ㆍ 저자명
- 배주현,김유근
- ㆍ 간행물명
- 한국대기환경학회지
- ㆍ 권/호정보
- 1999년|15권 5호|pp.599-611 (13 pages)
- ㆍ 발행정보
- 한국대기환경학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Now that the plume of point source was suspected to have strong impact on visibility impairment in Pusan, we evaluated visibility impairment impact of the pulme from Pusan Thermo Electric Power Plant in Pusan. Level-1 and-2 analyses were carried out using VISCREEN(Visual Impact Screen model). The emission rates for this Pusan Thermo Electric Power Plant was projected to be 116g/s of nitrogen oxides(as $NO_2$). The source fails the level-1 test with a Plume perceptibility(ΔE) of 30, nearly 15 times the screeing threshold. To characterize worstcase meteorological conditions for level-2 screening, we obtained meteorological data from Mar., 1996 to Feb., 1997 of Pusan Thermo Electric Power Plant. The source fails the level-2 test with a ΔE of 17, nearly 8.5 times the screening threshold. These analyses indicated that adverse visibility impairment could not be ruled out. Therefore a Level-3 analysis was performed using PLUVUE II(Plume Visibility model). As a result, maximum reduction of visual range for 0900LST in winter was 0.9%. Visual impact of the plume from vast point source was judged to be considerable in terms of background visibility of urban area.