- 공압 전달관의 동적 응답
- Dynamic Response of Pneumatic Transmission Lines
- ㆍ 저자명
- 박현우,박종호,신필권,심우건
- ㆍ 간행물명
- 소음진동
- ㆍ 권/호정보
- 1999년|9권 2호|pp.285-294 (10 pages)
- ㆍ 발행정보
- 한국소음진동공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Transient analysis for compressible fluid flow has been performed experimentally and analytically to study the dynamic characteristics of the end volume transmission lines following a sudden pressure change a its entrance. The numerical method was developed based on the method of characteristics. The sudden pressure at its entrance was generated by rupture of diaphragm in a shock tube. The sudden pressure was used to obtain the response, as input signal for the numerical analysis. The response to the sudden pressure at the end volume was measured using a pressure transducer. The experimental result shows good agreements with the numerical result. The effects of tube length, its diameter and end volume magnitude are evaluated on the responses of the pressure and on the damping factor. It is found that the viscous damping effects on the response through the transmission pipeline becomes larger with increasing pi;eline length and decreasing diameter of the pipe and the fluid-elastic stiffness decreases with increasing the terminal volume. The numerical approach presented in this paper can be very useful in designing the instrument and control system.