Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser
  • Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser
저자명
Kang. Seong-Kwon,Chu. In-Cheol,No. Hee-Cheon,Chun. Moon-Hyun,Sung. Chang-Kyung
간행물명
Journal of the Korean Nuclear Society
권/호정보
1999년|31권 6호|pp.548-560 (13 pages)
발행정보
한국원자력학회
파일정보
정기간행물|ENG|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.