기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 III. 발육황체와 퇴행황체의 감별
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 III. 발육황체와 퇴행황체의 감별
  • Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows III. Differential Diagnosis between Developing and Regressing Corpus Luteum
저자명
손창호,강병규,최한선,임원호,강현구,오기석,신종봉,서국현
간행물명
韓國臨床獸醫學會誌= Korean journal of veterinary clinical medicine
권/호정보
1999년|16권 1호|pp.118-127 (10 pages)
발행정보
한국임상수의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The aim of this study was to establish the method of differential diagnosis between developing and regressing corpus luteum in cows. Plasma progesterone (P$_4$) concentrations were determined by radioimmunoassay in slaughtered, cycling and pregnant cows. Ultrasonography was used to measure the corpus luteum size and histogram values for determining the correlationships between corpus luteum area or histogram values and plasma P$_4$ concentrations. The corpora lutea were monitored in vitro (water-bath scanning) by using ultrasonography with 7.5 MHz linear-array transducer in 196 slaughtered cows. The correlation coefficient between corpus luteum area and plasma P$_4$ concentrations was 0.46 (p<0.01), and between histogram values and plasma P$_4$ concentrations was -0.44 (p<0.01), respectively. The corpora lutea were monitored by ultrasonography with 5.0 MHz linear-array transrectal transducer in 188 cycling and 30 pregnant cows. The corpus luteum areas and plasma P4 concentrations were significantly different between regressing and other corpora lutea (p<0.01), and also histogram values were significantly different between regressing and developing corpola lutea (p<0.01). The correlation coefficients between corpus luteum areas and plasma P$_4$ concentrations were 0.76 (p<0.01), 0.71 (p<0.01), 0.65 (p<0.05) and 0.68 (p<0.05), and between histogram values and plasma P$_4$ concentrations were 0.74 (p<0.05), 0.71 (p<0.01), -0.52 (p<0.05) and 0.65 (p<0.05) in developing, functional, regressing and pregnant corpora lutea, respectively. These results indicate that corpus luteum areas and plasma P$_4$ concentrations were highly correlated in all stages of corpus luteum. The histogram values and plasma P$_4$ concentrations were positive correlated in developing, functional and pregnant corpora lutea, but negative correlated in regressing corpus luteum. Therefore, the measurement of corpus luteum area and histogram value by ultrasonography is reliable method for the assessment of luteal function, specially developing and regressing corpus luteum.