기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
유동층 연소로에서 진동형 공급기의 고체혼합 및 충전물에 대한 압력요동 특성
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 유동층 연소로에서 진동형 공급기의 고체혼합 및 충전물에 대한 압력요동 특성
  • The Characteristics of Solid Mixing in a Vibrating Type Feeder and Pressure Fluctuation of Packing Materials for a Fluidized Bed Combustor
저자명
김미영,김의식
간행물명
한국산업안전학회지
권/호정보
1999년|14권 3호|pp.101-109 (9 pages)
발행정보
한국안전학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

This study attempts to analyse the solid mixing in the feeder and the packing effect for pressure fluctuations in the fluidized bed. To study the mixing characteristics of solid in vibrating feeder for the stable operations of fluidized combustion, the system consisted of two groups of particles such that fine particles were located on the top of the coarse particles before vibratory mixing had started. The effects of packing materials on the pressure fluctuations in a fluidized bed were analysed by using a statistical method to interpret the behavior of fluidized bed. The experiments were carried out in a fluidized bed of 6.7cm-ID, and the experimental variables were particle sizes, of 115 to 1,015$mu extrm{m}$ in diameter and the multi-sized particles haying Rosin-Rammler and Gaussian distributions. The settled bed heights of particles to diameter ratios (L/D) were ranged from 0.5 to 2.0. And fluidizing of particles was carried out by air. The packing materials used were screen packing, and the properties of the pressure fluctuations in the fluidized bed were measured by a differential pressure transducer. The properties of the pressure fluctuations calculated were the mean, the standard deviation, and the major frequency of the power spectral density functions. From the characteristics of fluidizing, it was found that the standard deviation of pressure fluctuations could be effectively used to explain the fluidized phenomena, and the packing materials affected severely the properties of the pressure fluctuations. As a result, from the interpretation by spectral analysis, the effects of measuring radius of pressure fluctuations on standard deviation were constant in the case of the fluidized bed with and without packing materials. However, the effects of measuring the height of pressure fluctuations on standard deviations were linear increasing for the fluidized bed with packing materials, but were constant for the fluidized bed without packing materials at 4.5cm above the gas distributor. The major frequency of pressure fluctuations was found to be nearly independent of fluidized system. Also, the major frequency of pressure fluctuations decreased with increasing packing size, and it had maximum value at 10% of the packing amount.