전동 file을 장착한 Tri Auto ZX?의 치근단공 인지 정확도 평가
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 전동 file을 장착한 Tri Auto ZX?의 치근단공 인지 정확도 평가
저자명
박정원,Park. Jeong-Won
간행물명
大韓齒科保存學會誌
권/호정보
1999년|24권 4호|pp.578-584 (7 pages)
발행정보
대한치과보존학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The purpose of this experiment was to determine: (1) the safe automatic apical reverse setting that prevents overinstrumentation of the root canal, using Tri Auto ZX$^{(R)}$ and (2) the effect of various irrigant on such instrumentation. The instrumentation was carried out with the automatic apical reverse setting of 0.5, 1.0, 1.5, and 2.0. The root canal irrigants used in usual manner were normal saline(0.9%), NaOCl(2.5%), and RC Prep$^{(R)}$. For each reverse setting and each irrigant, ten teeth were used with the total of 120 teeth. The distance between the file tip and the apical constriction was determined by stereomicroscope using the point that the file began to rotate in reverse direction. When the reverse setting mode was set to 0.5, 18 of 30 were overinstrumented. If these were discriminated by irrigant, 10 of 6 with 0.9% saline, 10 of 6 with NaOCl, and 10 of 6 with RC Prep$^{(R)}$ has the file tip located 0.57${pm}$0.30mm, 0.73${pm}$0.39mm, and 0.26${pm}$0.25mm beyond the apical constriction respectively. In 1.0 setting 15 of 29 were over the apical constriction, and the distribution was 6 in saline, 5 in NaOCl, and 4 in RC Prep$^{(R)}$. The mean distance over the apical constriction was 0.28${pm}$0.13mm with saline, 0.75${pm}$0.61mm with NaOCl, and 0.25${pm}$0.17mm with RC Prep$^{(R)}$. When the autoatic reverse mode was set to 1.5, and 2.0, 5, and 1 teeth were found to be overinstrumented in respective settings. But there were large variations in overinstrumented distances when an attempt was made to compare the effect of irrigants on this overinstrumentations and they were meaningless for the small sample size. When all of the autoreverse setting were combined to compare the number of overinstrumented teeth with each irrigant, there were no significant differences (14 for normal saline, 12 for NaOCl, 13 for RC Prep$^{(R)}$). When 0.5 or 1.0 automatic apical reverse setting mode was used the Tri Auto ZX$^{(R)}$ in clinical application, the possibility of overinstrumentation beyond the apical constriction exists in 55.9% of cases. Therefore 1.5 or 2.0 setting is safer for the preparation inside the canal but this type setting needs additional apical hand preparation of the root canal because the accuracy is lower than 0.5 or 1.0 setting.