- 2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향
- ㆍ 저자명
- 김성준,민인홍,박명호,박민주,Kim. S. J.,Min. I. H.,Park. M. H.,Park. M. J.
- ㆍ 간행물명
- 한국전산유체공학회지
- ㆍ 권/호정보
- 2000년|5권 3호|pp.8-15 (8 pages)
- ㆍ 발행정보
- 한국전산유체공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.