- 멀티에어컨의 연결 배관길이의 변화에 따른 운전특성 변화
- ㆍ 저자명
- 박병덕,하도용,정백영,고재윤,임장순,Park. B.D.,Ha. D.Y.,Jeong. B.Y.,Koh. J.Y.,Yim. C.S.
- ㆍ 간행물명
- 태양에너지
- ㆍ 권/호정보
- 2000년|20권 4호|pp.45-52 (8 pages)
- ㆍ 발행정보
- 한국태양에너지학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
Multi A/C is consisted of one outdoor unit and several indoor units. When the Multi Air conditioner is installed, we have to be cautious of the length of pipe arrangements. When the pipe arrangement is installed with unbalance or too long, there can be cooling capacity losses and low EER. An experimental study was carried out about the operation characteristic of Multi Air conditioner varying the length of pipe arrangements. If the pipe arrangement of the system is 15m, the cooling capacity and EER were decreased 0.8% and 1.3% respectively compared to the case when pipe arrangement is 5m. In case of 25m, the cooling capacity and EER were decreased 10.7% and 12.2% respectively compared to the case of 5m. When the length of pipe is not same each other, it is profitable to make the pipe length of highest capacity indoor unit shortest.