기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석
  • THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS
저자명
조철,신상완,권종진,Cho. Chul,Shin. Sang-Wan,Kwon. Jong-Jin
간행물명
대한치과보철학회지
권/호정보
2000년|38권 5호|pp.724-743 (20 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.