Atmospheric concentrations of acidic pollutant were measured by the 4 stage filter pak method at Chunchon and by the 3 stage filter pack method at Seoul and Anmyon-do from January to December 1998. The sample was collected for 24 hours on every Wednesday. Concentrations of particulate matters were highest at Anmyon-do. The particulate concentration was much higher during the warm season than other seasons. While the particulate concentration was higher during the warm season, the concentration of gaseous matter was higher in winter. Dry deposition flux was calculated by using reported deposition velocities and concentration of pollutants measured in this study. The dry deposition velocities used in this study for SO$_2$, SO$_{4}^{2}$, HNO$_3$,NO$_{3}^{-}$ and NH$_3$ were 0.29, 0.15, 2.08( 2.13 only for Anmyon-do), 0.20 and 1.00cm/sec, respectively. At Chunchon, annual sulfur flux originated from dry deposition was 384 kg/$textrm{km}^2$, and the flux from wet deposition was 782kg/$textrm{km}^2$. Dry deposition of sulfur was 33% of total sulfur deposition. The annual nitrogen flux originated from dry deposition was 1,892kg/$textrm{km}^2$. And the flux from wet deposition was 1,066kg/$textrm{km}^2$. Dry deposition of nitrogen was 64% of total nitrogen deposition. Dry deposition as well as wet deposition have to be considerd in the study on acidification of environment such as soil or watershed.