기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
Ameroid Constrictor를 이용한 개에서의 단순 간외성 간문맥전신단락증의 치료
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • Ameroid Constrictor를 이용한 개에서의 단순 간외성 간문맥전신단락증의 치료
  • Surgical Correction of Single Extrahepatic Portosystemic Shunt Using Ameroid Constrictor in a Dog
저자명
정성목,이충호,양정환,김완희,최민철,윤정희,이주명,권오경,남치주
간행물명
Journal of veterinary clinics
권/호정보
2001년|18권 4호|pp.442-447 (6 pages)
발행정보
한국임상수의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

A 2-year-old 4.0-kg female Shih Tzu with history of hematemesis and melena was referred to Veterinary Medical Teaching Hospital, Seoul national University for further evaluation and treatment. During physical examination, the dog revealed mild depression, dry mucous membrane and abdominal pain. Hematologic values were normal and serum chemical values showed increased serum bile acid (53.47 umol/l, preprandial), fasting serum ammonia concentration (184 g/dl), alanine transferase (98 U/L), alkaline phosphatase (871 U/L) and gamma glutamyl transpeptidase (21 U/L), and decreased blood urea nitrogen (4 mg/dl), total protein (4.1 g/dl) and albumin (1.2 g/dl). Microhepatica was shown in abdominal radiography. During the ultrasound examination, dilated tortuous vein communicating with caudal vena cava ws observed near the stomach. Intraoperative jejunal vein portography was performed during laparotomy to confirm the location and size of shunt vessel. According to history taking, physical examination, hematologic and serum chemical examination and radiographic study, it was diagnosed as single extrahepatic portosystemic shunt. The anomalous vessel (7 mm, o.d.) that enter the caudal vena cava from the left gastric vein, near the level of the diaphragm, was identified. A Ameroid constrictor (5 mm, i.d.) was applied to the shunting vessel near the caudal vena cava. Hematologic and serum chemical values recovered gradually and were revealed normal values 4 months after surgery. Four month after surgery serum bile acids concentrations were 0.56 $mu$mol/l (preprandial) and 18.45 umol/l (postprandial). Abdominal radiograph showed normal gastric axis and it revealed normal size of the liver. Fine texture and increased echogenecity of liver and enlargement of portal vein were shown in ultrasonography. Single extrahepatic portosystemic shunt might be treated surgically using Ameroid constrictor.