기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
트리플루살 캅셀의 생물학적 동등성 평가
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 트리플루살 캅셀의 생물학적 동등성 평가
  • Bioequivalence Test of Triflusal Capsules
저자명
박정숙,이미경,박경미,김진기,임수정,최성희,민경아,김종국
간행물명
The journal of applied pharmacology : the official journal of the Korean Society of Applied Pharmacology
권/호정보
2001년|9권 4호|pp.291-297 (7 pages)
발행정보
한국응용약물학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The bioequivalence of two triflusal products was evaluated with 20 healthy volunteers following single oral dose according to the guidelines of Korea Food and Drug Administration (KFDA). Trisa $l^{R}$ capsule (Whanin Pharm. Corp., Korea) and Disgre $n^{R}$ capsule (Myung-In Pharm. Corp., Korea) were used as test product and reference product, respectively. Both products contain 300 mg of trifusal. One capsule of test product or reference product was orally administered to the volunteers, respectively, by randomized two period crossover study (2$ imes$2 Latin square method). Blood samples were taken at predetermined time intervals for 4 hours and the determination of trifusal was accomplished using semi-microbore HPLC equipped with automated column switching system. The analytical method with HPLC was validated according to the Bioanalytic Method Validation guideline by F7A prior to determining the plasma samples. The pharmacokinetic parameters (AU $C_{0-4h}$ $C_{max}$ and $T_{max}$) were calculated and ANOVA test was utilized for statistical analysis of parameters. As a result of the assay validation, the limit of quantification of trifusal in human plasma by current assay procedure was 50 ng/ml using 500 $mu$l of plasma. The accuracy of the assay was from 97.76% to 116.51% while the intra-day and inter-day coefficient of variation of the same concentration range was less than 15%. Average drug concentration at the designated time intervals and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05). The difference of mean AU $C_{olongrightarrow4hr}$, $C_{max}$, and $T_{max}$ between the two products (2.92, 4.39, and -2.44%, respectively) were less than 20%. The power (1-$eta$) and treatment difference ($Delta$) for AU $C_{olongrightarrow4hr}$ and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for $T_{max}$ was under 0.8, $T_{max}$ of the two products was not significantly different from each other (p>0.05). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating the two products of triflusal were bioequivalent.quivalent.ent.ent.