기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
임시 수복물 중합시 시간과 중합온도가 변연 적합도에 미치는 효과
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 임시 수복물 중합시 시간과 중합온도가 변연 적합도에 미치는 효과
  • EFFECT OF TIME AND TEMPERATURE ON THE MARGINAL FIT OF PROVISIONAL RESIN CROWN DURING POLYMERIZATION
저자명
윤승환,오남식,김일규,오성섭,최진호,김왕식,임영일,Youn. Seung-Hwan,Oh. Nam-Sik,Kim. Il-Kyu,Oh. Sung-Seop,Choi. Jin-Ho,Kim. Wang-Sik,Rim. Young-Il
간행물명
대한치과보철학회지
권/호정보
2001년|39권 5호|pp.514-525 (12 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

The purpose of this study was to compare the marginal fit of provisional restorations by differentiating the removal time and setting temperature during resin polymerization. After mixing autopolymerizing methyl methacrylate resin, the material was placed in a preformed resin shell crown. The crown was seated on a die with 1mm shoulder margin. Crowns were removed after 3, 4, 5, 6 minutes and polymerization was continued under the following conditions : $25^{circ}C$ air, $30^{circ}C,;40^{circ}C,;50^{circ}C,;60^{circ}C,;70^{circ}C$ water. After polymerization. the crown was sectioned. The marginal & occlusal discrepancies were measured. The mean marginal discrelpancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $96.6{mu}m.;84.6{mu}m,;86.7{mu}m$ and $105.6{mu}m$. The mean occlusal discrepancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $106.7{mu}m,;89.3{mu}m,;98.6{mu}m$ and $127.7{mu}m$. There was significant difference between 4 minutes group and 6 minutes group in occlusal discrepancies. The mean marginal & occlusal discrepancies for crowns polymerized in $25^{circ}C$ air were $98.2{mu}m$ and $124.1{mu}m$. The crowns polymerized in $50^{circ}C$ water demonstrated the smallest marginal & occlusal. discrepancies. The mean value of marginal & occlusal discrepancies in $50^{circ}C$ water were $73.1{mu}m$ and $77.5{mu}m$. These values were smaller than that of $25^{circ}C$ air. There were significant differences in the occlusal discrepancies between $25^{circ}C$ air and water conditions of $50^{circ}C$ water (${alpha}=0.05$) but. no significant difference in marginal discrepancies. There was no significant difference in the interaction between time and temperature. 4 minutes waiting time & $50^{circ}C$ water polymerizing condition produces the best fit at the margin of the provisional crown.