기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
열 순환에 따른 의치이장채의 물리적 성질의 변화에 관한 연구
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 열 순환에 따른 의치이장채의 물리적 성질의 변화에 관한 연구
  • A STUDY ON THE EFFECT OF THERMOCYCLING TO THE PHYSICAL PROPERTIES OF DENTURE LINERS
저자명
이동수,임헌송,임주환,조인호,Lee. Dong-Su,Lim. Heon-Song,Lim. Ju-Hwan,Cho. In-Ho
간행물명
대한치과보철학회지
권/호정보
2001년|39권 5호|pp.556-575 (20 pages)
발행정보
대한치과보철학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

For the improvement of denture fitness of changed residual ridge, denture liner can be used. Denture liner should be very stable physically in various environments of the mouth as well as be bonded strongly with denture resin. In this study. the specimens bonded with four kinds of soft denture liner and three kinds of hard denture liner were used to test the physical properties of the liners. All experimental groups were stored in $37{pm}1^{circ}C$ distilled water for 24hours, followed by thermocycling between $15^{circ}C$ and $45^{circ}C$ with 15 second dwell time. 1000, 2000, 3000 cycles of thermocycling were excuted and physical properties were measured by Instron Universal Testing Machine. The obtained results were as follows : 1. In tensile bond test of sea liners, it was shown that both of $Molloplast-B^{(R)}$ specimens before and after thermocycling had the highest tensile strength, and in case of hard liners, Dura-Liner $II^{(R)}$ specimen had the highest tensile strength before and after thermocycling. Depending on thermocycling, $Soft-Relining^{(R)}$, $Denture-Relining^{(R)}$, $Molloplast-B^{(R)}$, $Coe-Soft^{(R)}$ and $Kooliner^{(R)}$ specimen showed significant difference(p<0.05). 2. In strain test of soft liners, it was shown that $Molloplast-B^{(R)}$ specimen before thermocycling and the $Coe-Soft^{(R)}$ after thermocycling showed highest results, and in case of hard liners, the Dura-Liner $II^{(R)}$ specimen before and after thermocycling had the highest result. Depending on thormocycling, $Denture-Relining^{(R)}$, $Molloplast-B^{(R)}$ and Dura-Liner $II^{(R)}$ specimen showed significant difference(p<0.05). 3. In maximum distance test of soft liners. the $Molloplast-B^{(R)}$ specimen before thermocycling and the $Coe-Soft^{(R)}$ after thermocycling showed highest results. and in case of hard liners, the Dura-Liner $II^{(R)}$ specimen before and after thermocycling showed highest result. Depending on thermocycling, $Denture-Relining^{(R)}$, $Molloplast-B^{(R)}$ specimens showed significant difference(p<0.05). 4. In elasticity test of soft liners, the $Molloplast-B^{(R)}$ specimen before and after thermocycling showed highest result. and in case of hard liners, the Dura-Liner $II^{(R)}$ specimen before thermocycling and the $Tokuso-Rebase^{(R)}$ after thermocycling showed highest results. Depending on thermocycling, $Soft-Relining^{(R)}$ $Molloplast-B^{(R)}$ specimens showed significant difference (p<0.05).