- Implant system의 매몰조건과 소환온도에 대한 조사
- ㆍ 저자명
- 박근형,Park. Geun-Hyeung
- ㆍ 간행물명
- 대한치과기공학회지
- ㆍ 권/호정보
- 2001년|23권 1호|pp.115-121 (7 pages)
- ㆍ 발행정보
- 대한치과기공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
This study was investigated on effect of implant system about investment condition and burn out temperature. Posterior bridges were fabricated by using plastic sleeve and gold sylinder. The results were as follows; In plastic sleeve test and fitting cast copings. the phosphate bonded investment showed better gypsum bonded investment. The pure special liquid showed better margin fitness compared with mixed liquid (special liquid + distilled water). In gold cylinder test. the good burn out temperature of Ceramic PFG and Crown Gold was evaluated $0^{circ}C$ to $820^{circ}C$ and was decreased on $780^{circ}C$ for 30 minutes. $0^{circ}C$ to $750^{circ}C$ and was decreased on $650^{circ}C$ for 30 minutes.