- 스터링 극저온 냉동기 성능의 운전주파수 의존성에 관한 연구
- ㆍ 저자명
- 홍용주,박성제,김효봉,유병건,최영돈
- ㆍ 간행물명
- 한국초전도·저온공학회논문지
- ㆍ 권/호정보
- 2002년|4권 1호|pp.140-144 (5 pages)
- ㆍ 발행정보
- 한국초전도저온공학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
A free piston and free displacer (FPFD) Stirling cryocooler has been widely used for the cooling infrared and cryo-sensor. The thermodynamic performance of the free piston and free displacer type (FPFD) Stirling cryocooler is highly dependent on the operating frequency of the linear compressor and the natural frequency of the displacer. In this study, to find optimal relation between operating and natural frequency of the displacer the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stifling cryocooler has maximum cooling capacity at the operating frequency of about 0.8 times of the natural frequency of displacer. Therefore the operating frequency of the Stirring cryocooler should be determined by natural frequency of the linear compressor and displacer.