- 외란 억제 및 고장 분리를 위한 고유구조 지정기법
- ㆍ 저자명
- 서영봉,최재원,Seo. Young-Bong,Park. Jae-Weon
- ㆍ 간행물명
- 제어·자동화·시스템공학 논문지
- ㆍ 권/호정보
- 2002년|8권 5호|pp.357-362 (6 pages)
- ㆍ 발행정보
- 제어로봇시스템학회
- ㆍ 파일정보
- 정기간행물| PDF텍스트
- ㆍ 주제분야
- 기타
The underlying principle of fault detection via unknown input observer is to make the state estimation error independent of disturbances(or unknown inputs). In this paper, we present a systematic method that can exactly assign the eigenstructure with disturbance suppression and fault isolation capability. A desired eigenstructure for both fault isolation and disturbance suppression is obtained by an optimization method. For the dual purposes, terms for fault isolation and far disturbance suppression are included in the employed objective function for the optimization. The proposed scheme is applied to a simple example to confirm the usefulness of the method.