  • 가축 질병 이환상태의 확인을 위한 간이 체온계 개발에 관한 연구
  • Studies on the Development of Easy-checking Thermometer to Detect the Diseased Domestic Animals with fever
저자명
김용준,한경호,이창민,홍유미
간행물명
Journal of veterinary clinics
권/호정보
2002년|19권 1호|pp.28-36 (9 pages)
발행정보
한국임상수의학회
파일정보
정기간행물|
PDF텍스트
주제분야
기타
이 논문은 한국과학기술정보연구원과 논문 연계를 통해 무료로 제공되는 원문입니다.
서지반출

기타언어초록

These studies were carried out to develop some easy-checking thermometers instead of taking temperature of ectum for the farmers to detect easily a diseased animal with fever. Thermometers such as pincher-type, hood-type, raser-type, stick-type, and wrap-type were devised for the experiments. The experimental animals were cattle, horse, swine, aprine, and canine. Temperature-taking parts of the body were ear, shoulder, axilla, gluteal part, and coccygeal part according o the devised thermometer. Rectal temperature was taken at the same time for the comparison of temperature between rectum nd the certain part. The difference of temperature between rectum and shoulder part using eraser-type thermometer for the domestic animals were $3.37^{circ}C$ for cattle, $1.94^{circ}C$ for horses, $2.04^{circ}C$ for swine, $1.27^{circ}C$ for caprine, $0.9^{circ}C$ for canine. The difference of temperature between rectum and gluteal part using eraser-type thermometer for domestic animals were $3.46^{circ}C$ for cattle, $1.98^{circ}C$ for horses, $2.22^{circ}C$ for swine, and $1.1^{circ}C$ for canine. The difference of intra-individual temperature taken by eraser-type thermometer of shoulder and gluteal part were 0.3 and $0.8^{circ}C$ for cattle, 0.7 and $1.1^{circ}C$ for horses, 0.6 and $0.7^{circ}C$ for swine, 0.9 and $1.1^{circ}C$ for canine. The difference of temperature between rectum and shoulder part taken by hood-type thermometer for cattle was $3.93^{circ}C$ and the difference of intra-individual temperature was $0.8^{circ}C$. The difference of temperature between rectum and gluteal part taken by stick-type thermometer for cattle was $3.7^{circ}C$ and the difference of intra-individual temperature was $0.8^{circ}C$. The other types of thermometers than the above three were not proved to be reliable to detect temperature of domestic animals. It was concluded that hood-type, stick-type and eraser-type thermometers are recommendable devices of thermometer to detect easily the status of body temperature and that the eraser-type was proved to be a practical one of the thermometers used in this study.